WATER METER    DN 50 ~ 250
Application
--Measuring the volume of cold (hot) water passing through the pipeline
Feature:
--Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline;
--Dry-dial, Magnetic drive sensitive action, small pressure loss;
--Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service;
--Selected high quality materials for steady & reliable characteristic;
--Technical data conform to international standard ISO 4064.

WATER METER DN 50 ~ 250

DIMENSIONS

Type Size

L

Length

H

Height

Connecting flange  
φD1             Outside diameter φD2       Bolt circle diameter

Connecting Bolts

(n-M)

 
mm  
P-MAX-50 50 200 261 165 125 4-M16  
P-MAX -65 65 200 271 185 145 4-M16  
P-MAX -80 80 225 279 200 160 8-M16  
P-MAX -100 100 250 289 220 180 8-M16  
P-MAX -125 125 250 299 250 210 8-M16  
P-MAX -150 150 300 319 285 240 8-M20  
P-MAX -200 200 350 346 340 295 8-M20(1.0MPa)  
12-M20(1.6MPa)  
P-MAX -250 250 400 434 395 350 12-M20(1.0MPa)  
450 434 405 355 12-M24(1.6MPa)  
P-MAX -300 300 450 459 445 400 12-M20(1.0MPa)  
500 459 460 410 12-M24(1.6MPa)  
                   

NOTE: The flange dimension conforms to ISO7005-2:1988 standard. Order for products of special requirements is alsoaccepted.